Reyax
RYS8839: Ultra-Low Power, L1 L5 Dual-Band Multi-Constellation + 1.8V GNSS Module
Ultra-low power, L1 L5 Dual-band multi-constellation +1.8V GNSS module
Référence de l’article: VAR-827001975
Numéro de produit du fabricant: RYS8839
Code douane: 85177900
Disponible pour expédition immédiate: ${ $store.getters.currentItemVariation.stock.net }
Retard d'expédition prévu au-delà du stock disponible: 2 à 4 semaines
Article situé / expédié de : Riedlingen, Allemagne
13,72 EUR
*
Contenu
1 pièce
* Hors TVA hors Frais de livraison
Description
The RYS8839 is an ultra-low power, L1 L5 Dual-band multi-constellation GNSS module. It also has integrated digital noise filters for coexistence with other radio systems.
◆ SONY CXD5610GF Engine.
◆ A L1 L5 Dual-band GNSS receiver.
◆ Supports multi-constellation: GPS(L1C/A,L5) GLONASS(L1OF) BeiDou(B1I. B1C, B2a) Galileo(E1, E5a) QZSS(L1C/A, L1S, L1C/B, L5) NavIC(L5) SBAS(L1)
◆ Embedded digital noise filters and spectrum analyzer.
ID de l’art. | 101660 |
État | |
Modèle | RYS8839 |
Fabricant | Reyax |
Pays de fabrication | Taiwan |
Contenu | 1 pièce |
Poids | 110 g |
Poids net | 100 g |
Features
Specification
Item | Min. | Typical | Max. | Unit | Condition |
---|---|---|---|---|---|
Power Supply Voltage | 1.75 | 1.8 | 1.85 | V | VDD |
GNSS continuous mode
Item | Min. | Typical | Max. | Unit | Condition |
---|---|---|---|---|---|
Satellite acquisition Current | 24 | mA | L1+L5 Acquisition | ||
Satellite tracking Current | 16 | mA | L1+L5 Acquisition with 64-SV | ||
Idle Current | 2 | mA | Waiting for command | ||
Default Baud Rate | 115200 | bps | 8,N,1 | ||
Digital input level high | 0.7*VDD | VDD+0.3 | V | VIH | |
Digital input level low | -0.3 | 0.3*VDD | V | VIL | |
Digital output level high | 0.8*VDD | VDD | V | VOH 2mA | |
Digital output level low | 0 | 0.2*VDD | V | VOH 2mA | |
GNSS Center Frequency | 1176.45 1561.098 1575.42 1602.5625 | MHz | GPS L5 BeiDou GPS L1 Glonass | ||
Navigation update rate | 1 | 25 | Hz | ||
Accuracy | 1 | M | L1 L5 Signal strength is -130dBm | ||
Cold starts | 24 | Sec. | L1 L5 Signal strength is -130dBm | ||
Hot starts | 1 | Sec. | L1 L5 Signal strength is -130dBm | ||
Tracking Sensitivity | -167 | dBm | |||
Hot starts Sensitivity | -163 | dBm | |||
Cold starts Sensitivity | -149 | dBm | |||
Operating Temperature | -40 | 25 | +85 | ˚C | |
Dimensions | 11mm*8mm*2.2mm | ||||
Weight | 0.8 | g |